  • Battery : 1 Battery System
  • Waveform : Pure SINEWAVE
  • Input AC Range : Wide : 100V~300V AC, Standard : 180V~260V AC
  • Input DC Range : 10.5 ~ 14.2
  • Efficiency (on battery mode) : >80%
  • Protections: Overload : 110%, Short – Circuit : 300%
  • Charger Current All Models : STANDARD: 10A ± 1A, HIGH: 14A ± 1A

Rs.5,850.00 Rs.5,400.00

Email

MICRO CONTROLLER/DSC BASED INTELLI PURE SINEWAVE UPS SWE² is designed using latest state-of-the-art Technology for Better Performance and High Reliability. The INTELLIPURE SINEWAVE Technology used enhances the life of the battery and minimum effort has to be put for maintenance.

    • Digital Signal Controller (DSC) Based Intelligent Control Design

 

    • Pure Sine Wave Output

 

    • PWM Controlled multistage ATM (Automatic Trickle Mode) Charging

 

    • Display Indications (Status & Fault)

 

    • Smart Overload Sense and Short Circuit Protection

 

    • Easily Serviceable

 

    • Auto Reset Feature

 

    • Mains Input Voltage Range Selection

 

Smart Boost function for Low Input Voltage: When the mains voltage is low, the smart boost will correct it back to its normal range without draining the battery.
Smart Buck function for High Input Voltage: When the mains voltage is high, the AVR or smart buck will correct it back to its normal range without draining the battery.
Over Voltage Protection: The UPS will switch to UPS mode & offers power from the battery when the mains voltage is too high.
Over Load/Short Circuit Protection: If the UPS is excessively overloaded in UPS mode or encounters a short circuit, it will go into protection mode. The output will be shutdown in this case.
Battery Deep Discharge/Over Charge Protection: The UPS has in-built electronic protection circuit which protects the batteries from getting deep discharged or over charged.

 

Technical Specifications
Input Voltage
(Standard Range)
(Narrow Range)
:
100V~300V
180V~260V
Output Voltage on Mains Mode
:
Same as Input
Output Voltage on UPS Mode
:
210V ± 10%
Output frequency on UPS Mode
:
50 Hz ± 0.1 Hz
Switching from Mains to UPS
and from UPS to Mains
:
Automatic
Output Waveform on Mains Mode
:
Same as Input
Output Waveform on UPS Mode
:
PURE SINE WAVE
Battery Charging Current
:
Constant Charging Approx 10% of The Rated Battery Current in AH
Charger
:
Power Factor Controlled Boost Technology
Efficiency
:
> 80%
UPS Overload / UPS Short Circuit
:
110% / 300%
UPS Transfer Time
:
15 msec.
Technology
:
MICRO CONTROLLER / DSP BASED DESIGN
Auto Reset Feature
:
Yes